Circuit Protection

Air Circuit Breakers (ACB) 630A to 2500A

Draw-out air circuit breakers engineered to IEC 60947-2 for main incomer, transformer and generator protection. Four 3-pole frame sizes cover 630A to 2500A with breaking capacities up to 120kA, so a single platform can carry the whole low-voltage switchgear bill of materials.

Typical lead time 7-15 days · MOQ confirmed per model and accessory set

Walax COW1 series draw-out air circuit breaker (ACB) 630A to 2500A, 3-pole, IEC 60947-2
630-2500 ARated current, four 3-pole frames
up to 120 kARated ultimate breaking capacity Icu
1000 VRated insulation voltage Ui
Draw-outChassis type, 4-pole on request
Product Range

COW1 Series Model Lineup

Four frame sizes share one platform, one accessory range and one set of panel dimensions. Compare the ratings below, then open the model you need for the full specification table.

Walax COW1 series air circuit breaker model comparison, 630A to 2500A
ModelInUeUiIcuIcsIcw (1 s)PolesType
COW1-630/3Ref. HT-06/3630 AAC 400/690 V1000 V80 kA65 kA65 kA3PDraw-out
COW1-1000/3Ref. HT-10/31000 AAC 400/690 V1000 V80 kA65 kA65 kA3PDraw-out
COW1-1600/3Ref. HT-16/31600 AAC 400/690 V1000 V120 kA100 kA100 kA3PDraw-out
COW1-2500/3Ref. HT-25/32500 AAC 400/690 V1000 V80 kA65 kA65 kA3PDraw-out
Choose Your Rating

630A, 1000A, 1600A and 2500A in Detail

Each frame below lists the parameters that drive panel design – rated current, insulation level, breaking capacity and short-time withstand current. All four share the same 1000V insulation level and IEC 60947-2 approval.

Walax COW1-630/3 draw-out air circuit breaker 630A 3-pole
630 A · 3-pole · draw-out

COW1-630/3 Air Circuit Breaker · Ref. HT-06/3

The 630 A frame is the workhorse for sub-main and feeder protection in plant distribution boards and small transformer incomers. The draw-out chassis lets a spare breaker be exchanged without isolating the whole panel.

Rated current In630 A
Rated voltage UeAC 400 / 690 V
Rated insulation voltage Ui1000 V
Rated impulse withstand Uimp12 kV
Rated ultimate breaking capacity Icu80 kA
Rated service breaking capacity Ics65 kA
Short-time withstand current Icw (1 s)65 kA
Poles / installation3P / draw-out (4P, fixed type on request)
StandardIEC 60947-2 · GB/T 14048.2
Request COW1-630/3 price
Walax COW1-1000/3 draw-out air circuit breaker 1000A 3-pole
1000 A · 3-pole · draw-out

COW1-1000/3 Air Circuit Breaker · Ref. HT-10/3

A 1000 A frame for 800-1250 kVA transformer secondaries and generator output protection, keeping the same 80 kA breaking capacity and accessory range as the 630 A frame.

Rated current In1000 A
Rated voltage UeAC 400 / 690 V
Rated insulation voltage Ui1000 V
Rated impulse withstand Uimp12 kV
Rated ultimate breaking capacity Icu80 kA
Rated service breaking capacity Ics65 kA
Short-time withstand current Icw (1 s)65 kA
Poles / installation3P / draw-out (4P, fixed type on request)
StandardIEC 60947-2 · GB/T 14048.2
Request COW1-1000/3 price
Walax COW1-1600/3 draw-out air circuit breaker 1600A 3-pole
1600 A · 3-pole · draw-out

COW1-1600/3 Air Circuit Breaker · Ref. HT-16/3

The 1600 A frame steps up to 120 kA Icu and 100 kA Icw for high fault-level industrial systems and main incomers on 2000 kVA-class transformers.

Rated current In1600 A
Rated voltage UeAC 400 / 690 V
Rated insulation voltage Ui1000 V
Rated impulse withstand Uimp12 kV
Rated ultimate breaking capacity Icu120 kA
Rated service breaking capacity Ics100 kA
Short-time withstand current Icw (1 s)100 kA
Poles / installation3P / draw-out (4P, fixed type on request)
StandardIEC 60947-2 · GB/T 14048.2
Request COW1-1600/3 price
Walax COW1-2500/3 draw-out air circuit breaker 2500A 3-pole, complete front view
2500 A · 3-pole · draw-out

COW1-2500/3 Air Circuit Breaker · Ref. HT-25/3

The 2500 A frame carries heavy main incomer and bus-tie duty in a compact 3-pole chassis, so maximum current fits the smallest practical switchgear footprint.

Rated current In2500 A
Rated voltage UeAC 400 / 690 V
Rated insulation voltage Ui1000 V
Rated impulse withstand Uimp12 kV
Rated ultimate breaking capacity Icu80 kA
Rated service breaking capacity Ics65 kA
Short-time withstand current Icw (1 s)65 kA
Poles / installation3P / draw-out (4P, fixed type on request)
StandardIEC 60947-2 · GB/T 14048.2
Request COW1-2500/3 price
One Platform, Four Frames

COW1 Series 630A - 2500A

Same accessories, same panel cut-out family, same spare-parts stock. Distributors can carry one breaker platform and cover the full low-voltage incomer range.

Walax COW1 series air circuit breakers 630A, 1000A, 1600A and 2500A draw-out type
Walax COW1 series air circuit breakers - 630A, 1000A, 1600A and 2500A draw-out frames
Technical Data

Common Specifications & Accessories

General technical data

StandardsIEC 60947-2 · GB/T 14048.2
Utilization categoryB
Rated frequency50 / 60 Hz
Rated operational voltage UeAC 400 / 690 V
Rated insulation voltage Ui1000 V
Rated impulse withstand voltage Uimp12 kV
Rated currents630 / 1000 / 1600 / 2500 A
Breaking capacityIcu 80-120 kA · Ics 65-100 kA
Short-time withstand currentIcw 65-100 kA / 1 s
Poles3P standard · 4P on request
InstallationDraw-out chassis · fixed type on request
Trip unitIntelligent electronic trip unit, adjustable Ir / Isd / Ii
Control circuitsShunt, closing and undervoltage releases · AC 230V

Releases and accessories

  • Shunt release, AC 230 V
  • Closing release, AC 230 V
  • Delayed undervoltage release, AC 230 V
  • Motor-operated mechanism, AC 230 V
  • Auxiliary and alarm contact blocks
  • Mechanical interlock for changeover and bus-tie duty
  • Draw-out chassis with connected / test / disconnected positions
  • Spare chassis for rapid breaker exchange

Accessory sets are configured per order. Send the single-line diagram and we will confirm the release, contact and interlock combination for each incomer.

Applications

Where the COW1 Series Is Specified

01

Main incomer & bus-tie

Incoming, bus-tie and sectionalising duty in low-voltage switchgear for plants, commercial buildings and utilities.

02

Transformer protection

Secondary-side main protection for distribution transformers up to 2000 kVA, with 65-100 kA short-time withstand.

03

Generator & changeover

Generator output protection and mechanically interlocked changeover combined with Walax ATS panels.

04

Process & infrastructure

Cement, mining, water treatment, data-centre UPS distribution and solar plant AC collection boards.

FAQ

Frequently Asked Questions

An air circuit breaker uses air as the arc-extinguishing medium and is built as a draw-out unit for main incomer duty, typically 630A and above. An MCCB is a compact molded-case device, normally 16A to 1600A, used for feeder and branch protection. In most panels the ACB sits at the incomer while MCCBs distribute downstream.
Four 3-pole draw-out frames: COW1-630/3 (630A), COW1-1000/3 (1000A), COW1-1600/3 (1600A) and COW1-2500/3 (2500A). Rated ultimate breaking capacity is 80kA for the 630A, 1000A and 2500A frames and 120kA for the 1600A frame.
Yes. 4-pole and fixed-type versions are available on request, together with panel-mounting chassis and mechanical interlocking for changeover duty.
Shunt, closing and delayed undervoltage releases plus motor-operated mechanisms at AC 230V, along with auxiliary contacts, alarm contacts, mechanical interlocks and intelligent electronic trip units.
IEC 60947-2 type-test reports and CE / RoHS documentation accompany every shipment. SONCAP, PVOC, SABER and other market-specific certificates can be arranged on request.
Standard ratings ship in 7-15 days after order confirmation and deposit. MOQ depends on the model and accessory combination – send your list and we will confirm both.
Get In Touch

Send Us an Inquiry

Product Inquiry
Wholesale & Project Supply

Need Air Circuit Breaker Pricing?

Send your ratings, quantities and target port – our export desk replies with a full quotation, accessory list and packing plan.

Packaging, Shipping & Ordering Terms

MOQ, lead time, payment terms and packing quantities vary by model and accessory set. Contact us for MOQ and packing details for the ratings you need.

WhatsApp Email Inquiry